Technical Support Manual – 05/2018 Rel. 2.1.3 Page 30
How to exit the MOTO wheel type calibration
At any time it is always possible to exit the calibration procedure during its progress by pressing repeatedly [F+P3] keys
The machine will return to the SERVICE mode displaying the writing SER SER. To return to the NORMAL
mode, press [F+P3] keys again. The calibration in progress will be cancelled and the machine will use the
values of MOTO wheel type calibration which were previously stored. Also in this case the MOTO wheel type and the ALU1 Program
Type will remain set. The wheel dimensions will be those which were automatically set by the machine for this kind of calibration.
7. ERROR CODES AND WARNINGS
The machine indicates error conditions by alternating the display of the error code with a brief description (in English) of the cause
of the error.
The machine displays the code for different times depending on the code of said error, as indicated in the "Display" column in table
T7.1.
Table T7.1: Error codes
000 a 009 INT ERR MEC
ERROR: Machine parameters
internal error.
010 REV SPN MEC
ERROR: Reverse rotation of
the wheel.
Replace power supply board.
020 NO EEP MEC
5-10-15-20
CONFIRMATION
ERROR: Lack of
communication with the
eeprom memory.
Turn the machine off and then on again. If the
error persists, replace the CPU.C1C.X board.
011 SPD LOW MEC
low.
- Check the mains voltage.
- Check the tension of the belt and pulley.
012 NO STP MEC
5-10-15-20
ERROR: The wheel cannot be
stopped at the end of the
Check the power supply board.
013 SPD HIG MEC
high.
Replace the power supply board.
014 NO SPN MEC
5-10-15-20
ERROR: The wheel does not
spin.
1. Power supply board.
2. CPU.C1C.X board.
015 Codice
tasto
MEC
5-10-15-20
OFF
activation.
Release all buttons, then turn off or restart the
machine. If the error persists, replace the
CPU.C1C.X board.
016 DIS OUT MEC
10-15-20
ACTION
CONFIRMATION
WARNING: Distance sensor is
not in rest position at start-up
of the machine or when [P8]
Start is pressed.
Set the sensor to its rest position: the error
should disappear. If the error persists, contact
technical support.
NOTE: if [F+P2] is pressed the machine
acquisition system is temporarily disabled and
operation can be continu
status will last until the machine has been
turned off. The red LED [6] in figure F3.1 flashes
to indicate the temporary disabled status.
017 LAR OUT MEC
10-15-20
ACTION
CONFIRMATION
not in rest position at start-up
of the machine or when [P8]
Start is pressed.
Set the sensor to its rest position: the error
should disappear. If the error persists, contact
technical support.
NOTE: if [F+P2] is pressed the machine
acquisition system is temporarily disabled and
operation can be continued. The disabled
status will last until the machine has been
turned off. The red LED [6] in figure F3.1 flashes
to indicate the temporary disabled status.
019 NO CP MEC
5-10-15-20
CONFIRMATION
processor failure.
Turn the machine off and then on again. If the
error persists, contact technical support.
The machine can still be used but all functions
related to the USB port are disabled.