IntelliCarb Drop-In Ice Cooled Installation Guide
© 2003-2017, Cornelius Inc. - 15 - Publication Number: 630460204INS
16. Turn CO2 source on. Set secondary regulator for BIB pumps (located on side of rack) at 60 psi min. Bleed
carbonator.
17. Fill bin with ice.
18. Plug in Pump Motor and valve transformer.The carbonator tank should fill in 7 to 12 seconds.Open each
valve until carbonated water comes out.
Figure 14.
19. Connect syrup lines to bag-in-boxes. Bleed syrup from each valve.