TROUBLESHOOTING
IMPORTANT:
!
Sanitize Shots & Renew units before operation, refer to operator’s manual 620062762OPR for procedure.
FLAVOR SYRUPS DO NOT DISPENSE No 24 volt power to PC board.
• No CO
2
pressure.
Empty syrup tank.
• Kinked tubing.
• Clogged inner nozzle.
• Defective PC board.
• Defective harness from keypad.
Defective Flow control.
• Defective solenoid harness.
Defective keypad or ADA harness incorrectly
plugged in.
FLAVOR DISPENSES FOR MORE THAN 1 SEC Dip switch settings on control board incorrect.
• PC board defective.
• Defective flow control.
FLAVOR DISPENSES MORE THAN .5 OZ Dip switch settings on control board incorrect.
Flow control incorrectly set.
• PC board defective.
• Defective flow control.