KIT Base Unit ED175 Installation Instructions
Publication Number: 629097525INS - 14 - © 2016, Cornelius Inc.
TROUBLESHOOTING
Sanitize Shots & Renew units before operation, refer to operator’s manual 620062762OPR for procedure.
FLAVOR SYRUPS DO NOT DISPENSE • No 24 volt power to PC board.
• No CO
2
pressure.
• Empty syrup tank.
• Kinked tubing.
• Clogged inner nozzle.
• Defective PC board.
• Defective harness from keypad.
• Defective Flow control.
• Defective solenoid harness.
• Defective keypad or ADA harness incorrectly
plugged in.
FLAVOR DISPENSES FOR MORE THAN 1 SEC • Dip switch settings on control board incorrect.
• PC board defective.
• Defective flow control.
FLAVOR DISPENSES MORE THAN .5 OZ • Dip switch settings on control board incorrect.
• Flow control incorrectly set.
• PC board defective.
• Defective flow control.