9. Remove the oven together with the cell housing from the oven compartment back
plate. Remove the cell housing out of the oven. Use an appropriate cutting tool to
trim off the ½” tube of the cell housing at the mark.
!
Caution
Burrs created during the cutting process must be removed using the deburring tool or a
file prior to assemble the cell housing.
10. Install the pre-cut cell housing back to the oven. Re-attached the 1/8” T x 1/8” FNPT
elbow fitting to the other end of the cell housing.
11. Install a new oxygen sensor together with a new metal seal to the sensor housing.
Make sure the metal seal fully seat into the seal chamber of the cell housing.
Carefully tighten the oxygen sensor to the cell housing.
!
Caution
Care must be taken to make sure no dust, grease, or oil contact with the sensor.