13
interference in which case the user may be required to take adequate measures.
Input Over-Voltage
Protection
Input Under-Voltage
Protection
Maximum output
Power (1Min)
> 2000 VA~2300 VA (100%~115%)
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
200 / 220 / 230 / 240 VAC (± 3%)
(Dip Switch Selectable)
Pure Sine Wave (THD < 3%@ Normal Load)
Remote Controller
Panel Unit
6-port Green terminal (for inverter ON / OFF)
Over / Under Voltage, Reverse Polarity (Internal Fuse)
Over / Under Temperature Protection
(by Heat sink Temperature +80℃/-20℃)
Certified EN 55022 class A; EN 55024; EN 61000-3-2, -3-3
EN 61000-4-2, 3, 4, 5, 6, 8, 11
Certified CISPR 25; ISO 7637-2
Temperature & Load Controlled cooling Fan
AC Transfer Function Accessories
Table 8. SP-2000 for Output 200/220/230/240 VAC Specification.
Note:
Voltage range:Please refer to Figure 1
Normal load Condition:Vin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% load (PF=1.0)
Operating temperature:Please refer to Figure 2
Warning:This is a class A product. In a domestic environment this product may cause radio