Caution! Please follow the following steps for the installation
Before installing the inverter, make sure the main switch is at “OFF”
position.
Before using the remote function, make sure the main switch pressed
toward “REMOTE”
Use 20 ~ 24 #AWG wire to connect the remote control terminals
Figure 16. Wiring for control
3-2-3. General instruction before DC Input
3-2-3-1 Before installation:
The DC cables should be as short as possible (less than 6 feet / 1.8
meters ideally)
The size of the cable should be thick enough to limit the voltage drop to
less than 2% when carrying the maximum input current to prevent
frequent low-input voltage warnings, and shutdown.
The following sizes of cables and fuses are recommended distance (<6
ft.) between the batteries and the inverter.