C-SMART-
l Pro Uaar
Manual
8.2
Sound Volume
and
Screen
Brightness Adjustment
r::7'
NOTE
C-SMART·lPro Uoar
Manual
8.2.1Sound Volume
Adjustment
The sound
volume
can be
adjusted
to 4
different levels:
high.
low,
Minimum
and
limited
off_
Press the key 4
[._Ill,>]
in the idle state to
adjust
the sound
volume;
The sound
volume display
on the LCD panel
status area.
r::7'
NOTE
The last sound
volume
is
retained,
even
if
the power is turned
off.
8.2.2
Screen
Brightnes
s
Adjustment
The Screen
Brightness
can be
adjusted
to 4
different
levels.
Press the key 5
[•·:+:·]
in the idle state to
adjust
the screen
brightness;
The Screen
Brightness display
on the LCD panel Status
area.
r::7'
NOTE
The last Screen
Brightness
Is
retained,
even If the power Is turned
off.
8.3
Operation
The
device
can be
operated
in three
different modes:
CDM1 apex
locator
only;
M2 Motoronly;
@M3 as a
combined
unit (Dual
mode)when
the apex
location function
drives the
endo-motor.
One of the three
possible operating
modes is
selected
with the MODE
key
6
i•oo;l.on
the
operating
panel, the mode number
display
on the LCD
panel
Mode
area.
8.3.
1
M1
Apex locator only{wlthout
motor)
8.3.1.1 Connection
The
connection method
in this mode is shown in
chapter
7.3.5
(Fig.6).
When
turning
off the LED
lighting
function,
the LED delay time
function
can't be
selected.
Motor option area shows the state of LED
lighting:
P!l
Means LED
lighting function
is not
available;
P!iil
Means
lighting function
is
available
and the delay time is
3S.
8.3.2.8 Working
Start and stop the Motor
handpiece
·The
motor is
started
and
stopped
with the
ON/OFF
key on the
handpiece.
•If
you press the ON/OFF key briefly, the motor
handpiece starts.If you
re-press
the key, its
tops.
Manual
Reverse
·Press
the on
I
off
button
for more than 2
seconds
to
change
the
direction
of
file
rotation (whether
the motor is stopped or
running).
The
current
direction
of file
rotation
is
displayed
in the motor option
area:
Means
forward
rotation
Means
reverse rotation
r::7'
NOTE
Only
continuous
rotary file
systems
can change the
direction;
reciprocating
flle
systems
can not change the
direction.
Torque
bar
When the motor
handpiece starts
and its load
reaches approximately
half
of
the
preset
torque limit
value,
the torque bar
display•••••
,when the
load
approaches
the torque limit
value.
the torque bar
display
•••••
11
.
r::7'
NOTE
This
function
Is only
available
In
continuous
rotary file
system.