49
require this functionality. This may be handy when, for example, the camera covers the road
and an adjoining area. While it would be useful to have the motion detection enabled on the
area near the entrance to a building, it would most likely not be helpful to see it triggered every
time a car or truck passes by on the nearby road. Each channel has a specific regional motion
detecting setting.
To enter the “Regional Setting” menu, move the cursor
to “setting” and then press “Enter.” When viewing the
selected channel’s coverage area using the MD Area
option, the blue area is where motion detection is
activated, and transparent block is the area where
motion detection is not activated.
Press the direction keys on the remote control to move
the cursor along the small pane: the position of cursor is
indicated by a green frame. Press “Enter” to select or
cancel motion detection in this small pane. When the
setup is finished, press”
“or right click to return to the MD setup menu and click “
to save the settings.
Note:
Mouse operation: Left-click and drag the frame to set up the region for motion detection.
OUTPUT:” indicates that an alarm will be activated if it has been triggered by motion.
RECORD:” indicates that the selected channel will record if it has been triggered by
motion.
BUZZER:” indicates that the buzzer will sound if it has been triggered by motion.
Prerecord:” indicates that the relevant channel will prerecord for 5 seconds if it has been
triggered by motion.
Email/FTP:” indicates that a picture of selected channel will be sent to the pre-registered
email address and FTP if an alarm has been triggered by motion.
Mobile Alarm: ”indicates that an SMS message will be sent to the pre-registered phone
number when a motion-detection alarm has been triggered.
5.7 PTZ- (optional)
Move the cursor to “PTZ” (the icon will be
highlighted when selected) and press
“Enter” to access the PTZ settings interface.
A unique set of PTZ parameters can be set
for each channel. In this menu, users can
select values for each of the fields by
pressing the arrow buttons at each end of the
field. The changes will take effect after
clicking “
” to save the settings and
exiting the menu.