CTI 2572-B / 2500C-2572-B Installation and Operation Manual 75
The actual number of words written does
not match the requested number of
words.
The actual number of words written is
contained in the response message from
This error is probably caused by an
improperly programmed server node. If the
server is a PLC emulating a 2572-B server,
review the code and correct as required.
If the server is another 2572, contact CTI
The command cannot be used with a
Change the IP address to a unicast address or
change the command to one that supports
The address class is not supported by the
The response message contained an ID
field which did not match the ID field in the
command.
This error could be caused by a timeout value
which is too short followed by an attempt to
re-send. Therefore, by the time the response
to the first command arrives, you have
already sent a second command. You may
correct this condition by increasing the
timeout value.
This may also be caused by an improperly
programmed server. If the server is a PLC
emulating a 2572-B server, review the code
ETHERNET TRANSMISSION ERROR
The Ethernet port was unable to send the
If the problem persists, Contact CTI