Cleaning Out the Salt Storage Tank
A periodic clean-out of the Salt Storage Tank is necessary to keep your Culligan Water Softener at peak operating efficiency
Do it at least every 2 years when the salt supply is low
Follow these step-by-step procedures:
Tools needed:
Scoop
Clean, bucket-size container
Phillips-head screwdriver
Garden hose, Household scrub brush or sponge
1� Remove the salt storage tank cover and the cap from the brine valve chamber
2� Disconnect the brine line from the brine valve by holding in the outer ring of the push fitting, then pushing
the tubing in slightly before pulling it out�
3� Remove the nut securing the brine valve to the brine chamber, then lift the brine valve out of the brine valve
chamber and set aside in an upright position�
4� If you’d like to save any clean, dry salt remaining in the tank, remove it and place it in a clean container
5� Using the scoop, dig out and discard as much remaining salt, water and debris as possible�
6� Remove the brine valve chamber by removing the chamber retaining screw and nut�
7� Remove the salt plate at the bottom of the tank�
8� Lay the salt tank on its side and direct a brisk stream of water from your garden hose to its inside to rinse
out all residue�
9� Using a household scrub brush and a mild soapy solution, clean the salt plate�
This will complete the tank cleaning�
10� Re-insert the brine valve into the chamber, re-insert the brine line fully, and replace brine valve chamber cap�
11� Stand salt tank upright� Make sure to place the tank on a flat, smooth, solid surface�
12� Replace the salt plate� Place brine valve chamber in position and affix with screw and nut�
13� Insert the brine valve into the chamber and replace brine valve chamber cap�
14� Fill the salt storage tank with 4 to 6 inches of water
15� Fill the tank with salt to within a few inches of the top�
16� Replace salt storage tank cover
Troubleshooting
The Culligan Select Plus & Select Series Softener is equipped with an advanced error detection system� During all
operating modes the softener’s electronics are performing self-diagnostics to ensure that the unit is operating correctly
There may be times, however, when something may occur that could cause the unit to improperly operate� In those
instances the microprocessor will identify the exact problem and alert the user with a telephone handset symbol in the
upper left corner of the display and the error code will be shown�
For any additional troubleshooting or service needs please contact your local Culligan dealer
15
01040692 B 04/21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Culligan Aquasential Select Plus Series and is the answer not in the manual?

Culligan Aquasential Select Plus Series Specifications

General IconGeneral
BrandCulligan
ModelAquasential Select Plus Series
CategoryWater Dispenser
LanguageEnglish

Related product manuals