Do you have a question about the Culligan CSM Series and is the answer not in the manual?
Type | Reverse Osmosis System |
---|---|
Membrane Type | Thin Film Composite (TFC) |
Total Dissolved Solids (TDS) Reduction | Up to 99% |
Tank Capacity | 3.2 Gallons |
Operating Pressure | 40-80 psi |
Operating Temperature | 40-100°F |
Filtration System | Reverse Osmosis |
Outlines the manual's content and purpose.
Explains the use of special headings like Notice, Caution, and Warning.
Presents tables with flow rates and capacities for CSM softeners.
Details the ion exchange process for water softening.
Explains the steps of resin regeneration including backwash, brine draw, slow rinse, and fast rinse.
Illustrates the water flow during the service cycle of the softener.
Illustrates the water flow during the backwash cycle of the softener.
Illustrates the water flow during the brine draw cycle of the softener.
Illustrates the water flow during the slow rinse cycle of the softener.
Illustrates the water flow during the flush cycle of the softener.
Covers power, battery backup, EEPROM, AC outputs, and program updates.
Details features like Lock/Unlock, Time of Day, and Regeneration Interval.
Explains Aqua-Sensor, Flow Meter, Auxiliary Input, and Communication features.
Explains Time Clock, Flow Meter/Sensor, Progressive Flow, and Aqua-Sensor modes.
Provides diagrams for single, duplex, and triplex piping configurations.
Steps for positioning and preparing the softener tank.
Guidelines for connecting the softener to the water supply and drain.
Details the process of installing the brine refill valve.
Covers the installation of the brine tank and related piping.
Explains the installation of optional flow meters.
Guidelines for positioning paddlewheel flow sensors.
Instructions for installing Signet flow sensors.
Details the installation of turbine meters.
Steps for installing the gravel support bed in the resin tank.
Instructions for installing the optional Aqua-Sensor.
Steps for adding the water softening resin to the tank.
Details on mounting the MVP controller.
Instructions for connecting the tubing for the system.
Covers installation of solenoid valves for multi-tank systems.
Important precautions and guidelines for electrical installation.
Outlines the steps and diagrams for wiring the controller.
Guidelines for routing cables to the controller.
Shows the layout of the controller circuit board and its outputs.
Explains the transformer connection for power supply.
Details the wiring for the brine refill valve.
Covers communication cables and solenoids for multi-unit systems.
Information on blocking solenoids for specific system types.
Wiring diagrams for optional flow sensor meters.
Wiring diagram for the optional Aqua-Sensor.
Describes the function of auxiliary outputs on the controller.
Explains the use of the auxiliary input for signals.
Explains the use of DIP switches for programming the controller.
Defines the purpose and settings for each DIP switch.
Describes the layout and function of the MVP control keypad.
Instructions for setting up communication and IDs for multiple units.
Explains how resin amount and water chemistry determine system capacity.
Formula for calculating the batch set point for programming.
Guides the user through inputting programming data like Time of Day and Regeneration Time.
Sets the delay for the auxiliary input signal before initiating regeneration.
Sets the duration for backwash, brine/slow rinse, and return to slow rinse cycles.
Sets the frequency for regeneration initiation based on days or hours.
Allows setting regeneration for specific days of the week.
Sets the volume of water treated before regeneration is initiated.
Sets the maximum capacity before regeneration is triggered.
Establishes flow rate to trigger additional tanks in multi-unit systems.
Allows programming a delay to avoid back-to-back regenerations.
Controls the AUX 1 output based on contact status and cycle.
Configures the audible beeper for key presses.
Controls display blanking and locking/unlocking the programming.
Updates programs on connected controls from a master unit.
Provides a log for recording DIP switch settings for system programming.
Log for noting the method of regeneration initiation.
Log for recording program settings for each step.
Steps to manually advance through regeneration cycles.
Displays flow rate, capacity remaining, and total flow data.
Shows regeneration counts, days since last regen, and connected units.
Step-by-step instructions for pressurizing the media tank with water.
Procedure for removing air from the pilot valve tubing.
Instructions for performing the initial backwash cycle.
Guidelines for filling the brine tank with salt, distinguishing dry and wet storage.
Steps to manually cycle the valve to create brine for the first regeneration.
Final checks and customer advice before leaving the installation.
A checklist to ensure the system is properly installed and ready for service.
Procedure for sanitizing the water softener under specific conditions.
Steps involved in analyzing system problems and collecting data.
Schedule for routine inspections of system components and reasons for maintenance.
Describes the diagnostic feature to verify MVP control board operations.
Explains error codes ERR1, ERR2, ERR3, and ERR4 on the MVP control display.
Addresses leaks from pilot valve tubing, diaphragm valves, and pilot body.
Diagnoses high flow to drain, failure to draw brine, and restricted flow.
Troubleshoots diaphragm valves not closing or opening properly.
Addresses hard water leaks and restricted service/drain flow.
Troubleshoots pilot valve port issues and system standby/water provision.
Steps to safely shut down and depressurize the system for service.
Explains valve operation and flow control assembly service.
Details the function and service of backwash flow controllers.
Steps for disassembling and reassembling the backwash flow controller.
Procedure for testing the Aqua-Sensor probe with regenerated resin.
Troubleshooting sequence for systems that regenerate nightly.
Troubleshooting sequence for systems that never regenerate.
Instructions for removing the pilot valve assembly.
Steps for replacing the pilot drive motor assembly.
Instructions for reinstalling the pilot valve assembly.
Lists all available replacement parts for the CSM product line.
Details parts for resin tanks and their supports, including dimensions and quantities.
Lists parts and diagrams for the 2-inch Brunermatic D-180 Multiport Valve.
Provides part numbers and kits for 2" Brunermatic valve assemblies.
Lists parts and diagrams for the 3-inch Brunermatic D-180 Multiport Valve.
Provides part numbers and kits for 3" Brunermatic valve assemblies.
Lists parts for 1-inch injector assemblies, including flow rates.
Provides part numbers and kits for 1" injector assemblies.
Lists part numbers and backwash rates for automatic backwash flow controllers.
Lists parts and kits for the brine refill valve assembly.
Lists parts and kits for the Culligan MVP valve-mounted controller.
Details replacement kits for the MVP controller, including part numbers.
Lists complete brine systems and replacement parts for various tank sizes.
Guidelines for applying the Aqua-Sensor based on water parameters like hardness.
Shows recommended salt dosage based on water hardness levels.
Provides data on resin depth and capacity related to salt dosage.
Lists flow rate data for CSM series water softeners.
Provides K-factor data for various flow meters and installation types.
Explains the purpose of the operation log for tracking system performance and maintenance.