System Operating and Regulatory Specifications
In order to meet regulatory conditions, some operational parameters must be followed�
They include:
1� An operating water pressure between 22 and 125 psi (1�5–8�62 Bar)� Culligan recommends following the IAPMO
Uniform Plumbing code section 806�2 by installing a Pressure Regulating Valve if the water pressure is greater than 80
psi� Operating on pressures above the UPC for extended periods of time can increase the service frequency and failure
of replacement parts� On a private water system, make sure the minimum pressure (when the pump starts) is greater
than 20 psi (140 kPa)�
2� Operating temperature between 33° and 120°F or 0�5°–49°C�
3� Clear (non-turbid) water supplies (Less than 5 NTU)�
4� Using non-Culligan branded media or media from other sources or different amounts voids WQA certification�
5� To maintain WQA certification and continued PFAS reduction performance, use only Culligan supplied filter
medias specified in this manual�
Table 1� System Specifications�
Culligan Aquasential Whole Home PFAS Filter Systems
Indoor Indoor Outdoor Outdoor
Fiberglass Quadra-Hull™ Fiberglass Quadra-Hull™
Smart Flow Monitor Indoor Indoor Outdoor Outdoor
Tank Closure In/Out Head In/Out Head In/Out Head In/Out Head
Tank Size - Tank #1 10" x 54" 10" x 54" 10" x 54" 10" x 54"
Tank #1 - Media Calgon F600 GAC Calgon F600 GAC Calgon F600 GAC Calgon F600 GAC
Tank #1 - Media Volume 2�0 cu�ft� 2�0 cu�ft� 2�0 cu�ft� 2�0 cu�ft�
Tank #1 - Underbedding Cullsan, 20 lb Cullsan, 20 lb Cullsan, 20 lb Cullsan, 20 lb
Tank #1 - Overall Height 59" 59" 59" 59"
Tank Size - Tank #2 10" x 54" 10" x 54" 10" x 54" 10" x 54"
Tank #2 - Media Cullex PFAS Anion Cullex PFAS Anion Cullex PFAS Anion Cullex PFAS Anion
Tank #2 - Media Volume 1�5 cu�ft� 1�5 cu�ft� 1�5 cu�ft� 1�5 cu�ft�
Tank #2 - Underbedding Cullsan, 20 lb Cullsan, 20 lb Cullsan, 20 lb Cullsan, 20 lb
Tank #2 - Overall Height 60" 60" 60" 60"
Rated Service Flow @
Pressure Drop
7�5 gpm @ 7�5 psi 7�5 gpm @ 7�5 psi 7�5 gpm @ 7�5 psi 7�5 gpm @ 7�5 psi
Operating Pressure 20-120 psi 20-120 psi 20-120 psi 20-120 psi
Operating Pressure - Canada 20-90 psi 20-90 psi 20-90 psi 20-90 psi
Operating Temperature 33 - 120 F 33 - 120 F 33 - 120 F 33 - 120 F
Electrical Requirements 24 VDC, 1W 24 VDC, 1W 24 VDC, 1W 24 VDC, 1W
Electrical Power Consumption 0�5W / 1�0W 0�5W / 1�0W 0�5W / 1�0W 0�5W / 1�0W
pH Range 6�0 to 8�5 6�0 to 8�5 6�0 to 8�5 6�0 to 8�5
Iron <0�30 mg/l <0�30 mg/l <0�30 mg/l <0�30 mg/l
Manganese <0�05 mg/l <0�05 mg/l <0�05 mg/l <0�05 mg/l
Hardness < 10 gpg < 10 gpg < 10 gpg < 10 gpg
Hydrogen Sulfide None None None None
TOC - Total Organic Carbon < 2�0 mg/l < 2�0 mg/l < 2�0 mg/l < 2�0 mg/l
Turbidity 5 NTU 5 NTU 5 NTU 5 NTU
Sulfate 200 mg/l 200 mg/l 200 mg/l 200 mg/l
Chloride 100 mg/l 100 mg/l 100 mg/l 100 mg/l
* Total PFAS 0�00216 mg/L ± 20% 0�00216 mg/L ± 20% 0�00216 mg/L ± 20% 0�00216 mg/L ± 20%
* Including: PFBS; PFDA; PFHpA; PFHxS; PFNA; PFOA; PFOS� See the "Performance Data Sheet" on page 19 for details�
7
01045704 A 09/24
Specifications