Blue Ox Review of wiring diagrams [24 July 2007]
Curtis 1253 Manual, Rev. F
9
Blue Ox Rev. A, draft #1 [3 August 2007]
Fig. 3c Standard wiring configuration,
Curtis 1253 controller with Curtis 841 “Superspy” providing lift lockout.
1253 CONTROLLER
RxDATA
J2-1
GROUND (B-)
J2-2
TxDATA
J2-3
+15V
J2-4
M
J1-5
BATTERY
INTERLOCK
B+
M-
1311 PROGRAMMER
B-
INTERLOCK
J1-6
SS1
SS2
SS4
STATUS
J1-7
J1-8
J1-9
POT HIGH
J1-2
POT WIPER
J1-3
POT LOW
J1-4
THROTTLE
POT
J1-10
STATUS
SS3
SPEED SELECT SWITCHES
KEYSWITCH
J1-1
KSI
J1-12
CONTACTOR
CONTACTOR
CURTIS 841 “Superspy”
14
58
J1-11
LIFT LOCKOUT
841-6
841-5
841-4
841-3
Lift lockout is activated when the 841’s internal
relay between pins 3 and 4 is opened at 80%
battery discharge.
LOCKOUT TYPE should be programmed to 1.
A2
S1
SS1 SS2 SS3 SS4
2 — INSTALLATION & WIRING: Controller