5.0 GAS FLOW SURGE “PEAK” MEASUREMENT
5.1 Description
The GFM has a peak value "sample and hold" feature. This allows the user to
measure the maximum gas flow rate, which occurred during the welding cycle. The
maximum value is the result of a gas surge, which occurs when the gas solenoid is
activated. The trigger used to determine the time at peak is the “Max Limit” value.
The time above this level is measured and displayed. Whenever the Flow rate
exceeds this value the time is accumulated. When the flow stops the GFM will
display the Peak flow and the accumulated time above the max limit. When the flow
starts again the values are cleared and new values are displayed.
5.2 Setup
To enable the Peak flow and set the High limits and test parameters press both “▼”
and "" switch simultaneously to enter the “Select Para INC/DEC mode. The
first programmable parameter will appear on the display. To increment through the
program menus press the “▲” button. To decrement through the menus press the
▼” button. Until the “Enable Peak?” option is displayed. To edit a menu option
press both “▼” and "" switch simultaneously to enter the “Edit Para INC/DEC
mode. To toggle the option to “YES” press the “▲” button. To end the “Edit Para
INC/DEC” press both “” and "" switch simultaneously to exit and return to the
normal display mode. The “Peak= ### ##.# sec” window will be displayed and the
Peak function will be enabled.