INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) User’s manual
(c) Rack mount brackets x 2
(d) Stands x 2
(e) Telephone cable
(f) Emergency power o cable (gray)
(g) Serial cable x 2
(h) USB A+B type cable
PowerPanel® Business Edition software is
available on our website. Please visit www.
cyberpowersystems.com and go to the
Software Section for a free download.
OVERVIEW
The OR1500LCDRTXL2U/OR2200LCDRTXL2U
provides complete power protection from
utility power that is not always consistent. The
OR1500LCDRTXL2U features 1840 Joules of
surge protection and the OR2200LCDRTXL2U
features 2060 Joules of surge protection.
Both units provide long lasting battery backup
during power outages with maintenance
free batteries. The OR1500LCDRTXL2U/
OR2200LCDRTXL2U ensure consistent power
to your computer system and include software
that will automatically save your open files
and shutdown your computer system during a
utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The OR1500LCDRTXL2U/OR2200LCDRTXL2U
stabilizes inconsistent utility power voltage
to nominal levels that are safe for equipment.
Inconsistent incoming utility power may be
damaging to important data files and hardware,
but with Automatic Voltage Regulation (AVR),
damaging voltage levels are corrected to safe
levels. AVR automatically increases low utility
power and decreases high
utility power to a consistent
and safe 110/120 volts. If
incoming utility voltage
drops below 90 volts, or
exceeds 140 volts the units
automatically switch to
battery back-up power.
DETERMINE THE POWER
REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged
into the outlet does not exceed the UPS
unit’s rated capacity (1500VA/1125W for
OR1500LCDRTXL2U, 2190VA/1650W
for OR2200LCDRTXL2U). If the rated
capacities of the unit are exceeded, an
overload condition may occur and cause
the UPS unit to shut down or the circuit
breaker to trip.
2. There are many factors that can aect
the amount of power that your computer
system will require. It is suggested that
the load placed on the battery outlets not
exceed 80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may
be used immediately
upon receipt. However,
recharging the battery
for at least 8 hours is
highly recommended to
ensure that the battery’s
maximum charge
capacity is achieved.
A loss of charge may
occur during shipping
and storage. To
recharge the battery,
simply leave the unit
plugged into an AC
outlet.
2. With the UPS unit
turned o and unplugged, connect
your computer, monitor, and any other
peripherals requiring battery backup into
the battery power supplied outlets. Plug
the other peripheral equipments (printer,
scanner, speakers) into the full-time surge
protection outlets. DO NOT plug a laser
printer, paper shredder, copier, space
heater, vacuum, sump pump or other large
electrical devices into the UPS. The power
demands of these devices will overload and
possibly damage the unit.
-continued

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CyberPower OR1500LCDRTXL2U and is the answer not in the manual?

CyberPower OR1500LCDRTXL2U Specifications

General IconGeneral
Output power1125 W
Input frequency- Hz
Surge energy rating1840 J
Output power capacity1.5 kVA
EMI/RFI noise filteringYes
Power protection featuresOverload
Battery type12V, 7AH
Management platformSNMP, HTTP
Nominal input voltage90-140 V
Nominal output voltage120 V
AC outlet typesNEMA 5–15R
AC outlets quantity8 AC outlet(s)
Modem (RJ-11) ports2
USB 2.0 ports quantity1
Form factorRackmount/Tower
Cable length3 m
Display typeLCD
CertificationUL1778, cUL 107.3, FCC DOC Class B
Product colorBlack
Rack capacity2U
Battery technologySealed Lead Acid (VRLA)
Battery recharge time8 h
Typical backup time at full load7 min
Typical backup time at half load18 min
Operating temperature (T-T)0 - 35 °C
Operating relative humidity (H-H)0 - 90 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth477.52 mm
Width431.8 mm
Height88.9 mm
Weight26988.7 g