B. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
C. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder, pumps or other large electrical device to the UPS. The power
demands of these devices will possibly overload and damage your UPS.
D. Always plug the UPS into a 2 pole, 3 wire grounded receptacle/ wall outlet. Make sure the wall branch outlet is protected by a fuse or
circuit breaker and does not service equipment with large electrical demands, e.g. air conditioner, refrigerator, copier, etc. Avoid using
extension cords.
E. To prevent the risk of electric shock, follow the steps to ground the UPS:
(a) Connect an earth wire to the TVSS screw on the rear panel of UPS.
(b) Connect another side of the earth wire to Earth.
F. If your UPS freezes, you can do a hard reboot as below steps.
(a) Press and hold the power switch on the LCD module for around 10 seconds, the UPS will be forcibly shut down. All indicators, LCD
screen and output will be off immediately.
(b) Slightly press the power switch on LCD module once. The LCD screen will light up and show “UPS On/Off” on the first line. Use the
Up/Down button to select “On” or “Delay On” and then press the Enter button to turn on the UPS. The LCD screen will show
CyberPower in the first line and the UPS model in the second line. Then the Online or On Battery Indicator on the LCD module
lights up, indicating the UPS is operating from utility or battery.
Note: When the UPS is off, pressing and holding the power switch for around 10 seconds cannot turn on the UPS even though the
LCD screen will light up for a few seconds. Follow above steps to correctly turn on the product.
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. There are no user serviceable parts inside
except for the battery. For battery replacement, please refer to BATTERY REPLACEMENT section.
CAUTION! Turn off the unit and unplug it from the AC power source before cleaning.
CAUTION! Never immerse the unit in water or other liquids. Only use a soft, slightly damp cloth to wipe the surface of the unit. Do not use a
spray directly to clean or disinfect the unit.
To store the product for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every
three months to ensure battery life.
To prevent risk of fire or electric shock, install or place the unit in a temperature and humidity controlled indoor area, free of conductive
contaminants.