• ESD (Electrostatic Discharge) grounding strap
Disconnect power source
Unplug the power cord from the power outlet.
Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing
maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
Remove back cover
Remove four screws securing back cover to console assembly using a Phillips screwdriver.
Qty.DescriptionItem
1Console Assembly1
1Back Cover2
4Screws3
Remove wireless heart rate board
The wireless heart rate board is installed with double sided tape. Remove only if replacing with a new
wireless heart rate board.
1. Unplug the wireless heart rate cable by un-latching connector from the wireless heart rate board.
Qty.DescriptionItem
1Wireless Heart Rate Cable1
1Wireless Heart Rate Board2