Control X Plus
Connector
Number
Max
Current
Output
High-Side
Output
Low-Side
Signal
Input
Bilge
Sensing
Light
Dimming
H Bridge
Parallel
Circuits
RGB
Zone
Channel Notes
4x 15A High Side Outputs or 2x H-Bridge – 50A Connector Max
A1
15A
A2
15A
H-Bridge channels
A3
15A
can’t be paralleled
A4
15A
12x 10A High Side Outputs or 12x Full SI Inputs80A Connector Max
B1
10A
B2
10A
B3
10A
B4
10A
B5
10A
B6
10A
B7
10A
B8
10A
B9
10A
B10
10A
B11
10A
B12
10A
8x 5A Low Side Outputs or 10x Full SI Inputs, Shunt Input30A Connector Max
C1
Shunt Input (+)
C2
Full SI Only (Ignition Wake)
C3
5A
RGBW Z2 Red
C4
5A
RGBW Z2 Green
C5
5A
RGBW Z1 Red
C6
5A
RGBW Z1 Green
C7
5A
RGBW Z1 Blue
C8
5A
RGBW Z1 White
C9
5A
RGBW Z2 Blue
C10
5A
RGBW Z2 White
C11
Full SI Only (Ignition Wake)
C12
Shunt Input (-)
1 2
4 3
1 2
12 11
3 4
10 9
5
6
8 7
1 2
12 11
3 4
10 9
5 6
8 7
A
B C
10A high side outputs
Or
Signal Inputs
Shunt Input
5A low side outputs
or
Signal Inputs
Signal Inputs
Only
15A high side outputs
Or
2 x 15A H-Bridge
Figure 7. Control X PLUS Channel Specifications