STEP 1: Remove the existing non captive ending by removing the two (2) screws using a 4mm Allen Key:
STEP 2: Attach the piston adaptor with the four (4) provided screws. Apply some blue thread locker on the
screw threads then torque them to a value of 100 lbf·in (11 Nm) using a 4mm Allen Key: