Loading...
device. On the other hand, if the Remote-side operating system tries to write data to the redirected
device, the drive cache of the Host’s operating system might contain older data.
Because the operating systems are not aware that the drive is being redirected, they could try to
write data at the same time and therefore cause error messages to pop up. We therefore
recommend that the Remote user uses the Drive Redirection function with care, especially if write
support is enabled.
Disabling Drive Redirection
To disable the Drive Redirection function, click Disable Drive Redirection on the Virtual
Media > Drive Redirection screen and then click Apply.
Force read-only connections
If you enable the Force read-only connections function, write support for the Drive
Redirection feature will be switched off once you click Apply. This will make it impossible to
write on a redirected device, which is a safer option if you don’t want to take the risk of
file-system-destroying write-over collisions between the Remote and
63