17
# Function mode list #
Name
Function
Setting
출고시 기준설정값
F-01
Decimal point
0, 1, 2, 3
1
F-02
Division
1, 2, 5, 10, 20, 50
1
F-03
Display filter
0, 4, 8, 16, 32
8
F-04
Hold mode
Sample hold, Peak hold, Absolute peak hold
Peak hold
F-05
Comparison mode
Decision, High limit, Low limit
Decision
F-06
Hysteresis
0 ~ 99
0
F-08
DAC capacity
-19999 ~ +99999
10000
F-09
ID Number
0 ~ 32
0
F-10
Baud rate & PRINT
2400, 4800, 9600, 19200, 38400, 57600
9600
F-11
Auto zero tracking
0 ~ 99
0
F-12
Auto zero tracking time
0.0 ~ 5.0 sec
0.0
F-13
Force unit
Kg(kg/), N, b, bar, MPa
Kg
F-14
Key disabling
Zero key, Lo key, Hi key, Hold key
0000
F-01. Decimal point (Decimal point set up)
(Standard setup value: 1)
Display data
Setting
Remark
0
00000
: No decimal point
CH1, CH2
Individual setup
1
0000.0
: One decimal place
2
000.00
: Two decimal places
3
00.000
: Three decimal places