EasyManuals Logo

dacell DN-130L User Manual

Default Icon
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
17
# Function mode list #
Name
Function
Setting
출고시 기준설정값
F-01
Decimal point
0, 1, 2, 3
1
F-02
Division
1, 2, 5, 10, 20, 50
1
F-03
Display filter
0, 4, 8, 16, 32
8
F-04
Hold mode
Sample hold, Peak hold, Absolute peak hold
Peak hold
F-05
Comparison mode
Decision, High limit, Low limit
Decision
F-06
Hysteresis
0 ~ 99
0
F-08
DAC capacity
-19999 ~ +99999
10000
F-09
ID Number
0 ~ 32
0
F-10
Baud rate & PRINT
2400, 4800, 9600, 19200, 38400, 57600
9600
F-11
Auto zero tracking
0 ~ 99
0
F-12
Auto zero tracking time
0.0 ~ 5.0 sec
0.0
F-13
Force unit
Kg(kg/), N, b, bar, MPa
Kg
F-14
Key disabling
Zero key, Lo key, Hi key, Hold key
0000
F-01. Decimal point (Decimal point set up)
(Standard setup value: 1)
Display data
Setting
Remark
0
00000
: No decimal point
CH1, CH2
Individual setup
1
0000.0
: One decimal place
2
000.00
: Two decimal places
3
00.000
: Three decimal places

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the dacell DN-130L and is the answer not in the manual?

dacell DN-130L Specifications

General IconGeneral
Branddacell
ModelDN-130L
CategoryTouch Panel
LanguageEnglish