MODEL : DN-130L
DIGITAL INDICATOR
USER MANUAL
DACELL CO.,LTD.
Address : 681-1 Cheoksan-Ri, Nami-Myeon, Cheongweon-Gun,
Chung-buk
TEL :82-43-260-2242
FAX : 82-43-260-2245
http://www.dacell.com
E-Mail : info@dacell.com
Question and Answer IconNeed help?

Do you have a question about the dacell DN-130L and is the answer not in the manual?

dacell DN-130L Specifications

General IconGeneral
Branddacell
ModelDN-130L
CategoryTouch Panel
LanguageEnglish

Summary

Special Features

Calibration Method

Details two calibration systems: actual load and rated sensor output (mV/V).

Comparison Output

Covers setting upper/lower limits and outputting contact point signals.

Data Back-up

Notes that setup values are memorized on flash memory, preventing data loss.

Power

States the power requirement is AC 85 ~ 265V 50/60Hz Free voltage.

Attention

Attention for installation

Lists precautions for installation, such as avoiding wet places, high temperature, and using proper wiring.

Attention for use

Advises against inputting unstable loads during calibration and pressing keys arbitrarily.

Specification

Output

Details comparison output (HI/LO) and analog output (DC 0~10V / 4~20mA).

Power Supply

Lists power supply as AC 85~265V 50/60Hz free voltage.

Front Panel

F ZERO Key

Describes its function in measuring mode (zeroing) and setup mode (returning to measuring).

LO Key

Explains its function in measuring mode (display/change lower limit) and setup mode (move cursor).

HI Key

Details its function in measuring mode (display/change upper limit) and setup mode (increment value).

E HOLD Key

Describes its function in measuring mode (Hold/Cancel Hold) and setup mode (Save setup).

Rear Panel

AC_L, N

Identifies the main power supply wiring terminals.

Ground Terminal

Denotes the ground terminal for independent ground connection.

E1+

Specifies the CH1 Sensor Supply Voltage + connection terminal.

E1-

Specifies the CH1 Sensor Supply Voltage – connection terminal.

S1+

Specifies the CH1 Sensor Output Signal + connection terminal.

Attention

Lists critical wiring and usage precautions, including grounding and checking terminals.

Wiring Diagram

Setting Modes

Digital calibration (Calibration by sensor output value)

Explains calibration using rated capacity and rated output from a calibration sheet.

Actual load calibration

Describes calibration by applying actual load (standard weight) to the sensor.

Calibratuib by Shunt CAL Value

Details calibration using the S.CAL value without requiring standard weight.

Lock Set-up

Details how to prevent accidental operations by setting key locks.

Product Inspection

Transmission DATA form (INDICATOR -> PC)