NO COOLING FAN:
λ Check volt age at main relay board out of CLV relay for 120V. (after oven has
been preheated to 180 degrees or higher)
λ Open motor winding
NO SPARK TO BURNER:
λ Check ignitor post for cracks
λ Check for open ignitor wires or bad connection at push on terminal
λ Check Spark Switch that is mounted to valve for open and closed circuit
λ Check wires from spark switch to main harness that plug into spark module for a good
Page 15
connection and 120V at each spark switch
TROUBLESHOOTING