6/12
Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
9.2.2 [D-02] R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
9.2.4 [D-07] R/W
0: No
1: Yes
└─ Back up heater
9.3.1 [E-03] R/O
3: 6V (*1)
4: 9W
(
*2
)
9.3.2 [5-0D] R/W (*1)
R/O (*2)
0: 230V, 1~ (*1)
1: 230V, 3~ (*1)
2: 400V
,
3~
(
*2
)
9.3.3 [4-0A] R/W
1: 1/1+2 (*1) (*2)
2: 1/2
3: 1/2 + 1/1+2 in emer
g
enc
y
9.3.4 [6-03] R/W 0~10kW, step: 0,2kW
2kW (*1)
3kW
(
*2
)
9.3.5 [6-04] R/W 0~10kW, step: 0,2kW
4kW (*1)
6kW
(
*2
)
9.3.6 [5-00] R/W
0: No (*5)
1: Yes (*4)
9.3.7 [5-01] R/W -15~35°C, step: 1°C
0°C
9.3.8 [4-00] R/W 0: Disabled
1: Enabled
2: Onl
y
DHW
└─ Booster heater
9.4.1 [6-02] R/W 0~10kW, step: 0,2kW
0kW
9.4.3 [8-03] R/W 20~95 min, step: 5 min
50 min
9.4.4 [4-03] R/W 0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Le
g
ionella onl
y
└─ Emergency
9.5 [4-06] R/W 0: Manual
1: Automatic
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
9.5.2 [7-06] R/W
0: Disabled
1: Enabled
└─ Balancing
9.6.1 [5-02] R/W
0: Disabled
1: Enabled
9.6.2 [5-03] R/W -15~35°C, step: 1°C
0°C
9.6.3 [5-04] R/W 0~20°C, step: 1°C
10°C
9.6.4 [8-02] R/W 0~10 hour, step: 0,5 hour
0,5 hour
9.6.5 [8-00] R/W
0~20 min, step 1 min
1 min
9.6.6 [8-01] R/W 5~95 min, step: 5 min
30 min
9.6.7 [8-04] R/W 0~95 min, step: 5 min
95 min
Installer settings
9.7 [4-04] R/W
0: Intermittent
1: Continuous
2: Off
└─ Benefit kWh power supply
9.8.2 [D-00] R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.8.3 [D-05] R/W 0: Forced off
1: As normal
9.8.4 [D-01] R/W
0: No
1: Active open
2: Active closed
3: Smart Grid
9.8.6 R/W 0: No
1: Yes
9.8.7 Enable Room buffering R/W
0: No
1: Yes
9.8.8 R/W 0~20 kW, step: 0,5 kW
20 kW
└─ Power consumption control
9.9.1 [4-08] R/W
0: No limitation
1: Continuous
2: Di
g
ital in
p
uts
9.9.2 [4-09] R/W 0: Current
1: Power
9.9.3 [5-05] R/W 0~50 A, step: 1 A
50
A
9.9.4 [5-05] R/W 0~50 A, step: 1 A
50
A
9.9.5 [5-06] R/W 0~50 A, step: 1 A
50
A
9.9.6 [5-07] R/W 0~50 A, step: 1 A
50
A
9.9.7 [5-08] R/W 0~50 A, step: 1 A
50
A
9.9.8 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
Limit 3
Limit 4
Limit
Limit setting kW
Power consumption control
Type
Limit
Limit 1
Limit 2
Water pipe freeze prevention
Allow heater
Allow pump
Benefit kWh power supply
Allow electric heaters
Priority temperature
Offset BSH setpoint
Anti-recycle timer
Minimum running timer
Maximum running timer
Additional timer
Capacity
BSH eco timer
Operation
Emergency
Compressor forced OFF
Space heating priority
Configuration
Capacity step 1
Additional capacity step 2
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
Equilibrium temperature
Operation
DHW pump
Solar
BUH type
Voltage
4P644735-1A - 2022.03
(*1) *6V*_(*2) *9W*_
(*3) Only applicable for models where cooling is possible_
(*4) E_(*5) E7

Table of Contents