6 | Application guidelines
Installer reference guide
37
EPRA08~12EAV3+W1 + ETBH/X12EF6V+9W
Daikin Altherma 3 H MT W
4P634885-1 – 2021.03
Setting Value
Number of water temperature zones:
▪ #: [4.4]
▪ Code: [7-02]
0 (Single zone): Main
External room thermostat for the main
zone:
▪ #: [2.A]
▪ Code: [C-05]
1 (1 contact): When the used
external room thermostat or heatpump
convector can only send a thermo ON/
OFF condition. No separation between
heating or cooling demand.
Benefits
▪ Cooling. The heat pump convector offers, besides heating capacity, also excellent
cooling capacity.
▪ Efficiency. Optimal energy efficiency because of the interlink function.
▪ Stylish.
Combination: Underfloor heating + Heatpump convectors
▪ Space heating is provided by:
- The underfloor heating
- The heatpump convectors
▪ Space cooling is provided by the heat pump convectors only. The underfloor
heating is shut off by the shut-off valve.
Setup
A Main leaving water temperature zone
B One single room
a Heat pump convectors (+ controllers)
▪ For more information about connecting the electrical wiring to the unit, see:
- "9.2Connections to the outdoor unit"[4100]
- "9.3Connections to the indoor unit"[4108]
▪ The heat pump convectors are connected as follows:
- Warm water → Indoor unit
- Cold water → Outdoor unit
▪ A shut-off valve (field supply) is installed before the underfloor heating to
prevent condensation on the floor during cooling operation.