EasyManua.ls Logo

Daikin Altherma 3 R F - Yearly Maintenance; Yearly Maintenance Outdoor Unit: Overview; Yearly Maintenance Outdoor Unit: Instructions; Yearly Maintenance Indoor Unit: Overview

Daikin Altherma 3 R F
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 | Maintenance and service
Installer reference guide
257
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
14.2 Yearly maintenance
14.2.1 Yearly maintenance outdoor unit: overview
Check the following at least once a year:
Heat exchanger
14.2.2 Yearly maintenance outdoor unit: instructions
Heat exchanger
The heat exchanger of the outdoor unit can get blocked up due to dust, dirt,
leaves, etc. It is recommended to clean the heat exchanger yearly. A blocked heat
exchanger can lead to too low pressure or too high pressure leading to worse
performance.
14.2.3 Yearly maintenance indoor unit: overview
Water pressure
Magnetic filter/dirt separator
Water pressure relief valve
Relief valve hose
Pressure relief valve of the domestic hot water tank
Switch box
Descaling
Chemical disinfection
Pressure reducing valve of the domestic hot water tank kit
Temperature and pressure relief valve
14.2.4 Yearly maintenance indoor unit: instructions
Water pressure
Keep water pressure above 1bar. If it is lower, add water.
Magnetic filter/dirt separator
b
a
c
d
a Screw connection
b Magnetic sleeve
c Drain valve
d Drain cap
The yearly maintenance of the magnetic filter/dirt separator consists of:

Table of Contents

Other manuals for Daikin Altherma 3 R F

Related product manuals