EasyManua.ls Logo

Daikin Altherma 3 R F - Service Space: Outdoor Unit

Daikin Altherma 3 R F
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17 | Technical data
Installer reference guide
285
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
17.1 Service space: Outdoor unit
150
A~E H
B
H
D
H
U
a b c d e e
B
e
D
(mm)
≥300
≥300 ≥100
≥150
≥100
≥150
≥150
≥150
≥500
≥500
≥500
≥1000
≥500
≥1000
≥1000
≥1000
≥1000
≥1000
≥1000
≥1000
≥1000
≥1000
≥1000
≥1000≥300
≥300
≥300
≥300
≥300
≥300
≥300
≥500
≥500
≥500
≥500
≥500
≥500
B
A, B, C
B, E
A, B, C, E
A, C, D, E
A, B, C, D, E
D
D, E
B, D
A, C
B, D, E H
B
>H
D
(H
B
AND H
D
)
> H
U
(H
B
AND H
D
)
> H
U
(H
B
OR H
D
)
≤ H
U
(H
B
OR H
D
)
≤ H
U
H
B
<H
D
H
B
>H
D
(H
B
AND H
D
)
> H
U
(H
B
OR H
D
)
≤ H
U
H
B
<H
D
≤500
≤500
≤500
≤500
≤500
≤500
≤500
≤500
H
U
a
A
d
D
H
D
e
e
B
e
D
E
H
U
c
C
b
B
H
B
The symbols can be interpreted as follows:
A, C Right side and left side obstacles (walls/baffle plates)
B Suction side obstacle (wall/baffle plate)
D Discharge side obstacle (wall/baffle plate)
E Top side obstacle (roof)
a,b,c,d,e Minimum service space between the unit and obstacles A, B, C, D and E
e
B
Maximum distance between the unit and the edge of obstacle E, in the direction of
obstacle B
e
D
Maximum distance between the unit and the edge of obstacle E, in the direction of
obstacle D
H
U
Height of the unit including the installation structure
H
B
,H
D
Height of obstacles B and D
NOT allowed
NOTICE
Cascading outdoor units. Installation layouts with multiple outdoor units in
combination with floor-standing indoor units are NOT allowed.

Table of Contents

Other manuals for Daikin Altherma 3 R F

Related product manuals