Loading...
17 | Technical data
Installer reference guide
295
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
17.6 ESP curve: Indoor unit
4D128635A
0
40
80
100
60
20
30
70
90
50
10
A (kPa)
16 kW
B (l/min)
0 10 20 30 40 50 605 15 25 35 45 55
C D E
F
A External static pressure in the space heating/cooling circuit
B Water flow rate through the unit in the space heating/cooling circuit
C Minimum water flow rate during normal operation
D Minimum water flow rate during backup heater operation
E Minimum water flow rate during cooling operation
F Minimum water flow rate during defrost operation
Notes:
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
Make sure water quality complies with EU directive 2020/2184.
17.7 Technical specifications: Domestic hot water tank
17.7.1 Test results in accordance with EN12897 (2016)
INFORMATION
This unit has been tested and approved according to BSEN12897:2016
Description Hot water capacity Reheat time
EBVH16SU23DJ6V 200l 23min 05sec