8/10
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
9.I [6-05]
0
9.I [6-06]
0
9.I [6-07] R/W 0~200W, step: 10W
0W
9.I [6-08] R/W
2~20°C, step: 1°C
10°C
9.I [6-09]
0
9.I [6-0A] R/W 30~[6-0E]°C, step: 1°C
50°C
9.I [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.I [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.I [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
9.I [6-0E] R/W
40~75°C, step: 1°C
60°C [E-07]=0
40~80°C, step: 1°C
60
°
C
[E
-
07]
=
5
9.I [7-00] R/W 0~4°C, step: 1°C
0°C
9.I [7-01] R/W 2~40°C, step: 1°C
2°C
9.I [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
9.I [7-03]
2.5
9.I [7-04]
0
9.I [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
9.I [7-06] R/W
0: Disabled
1: Enabled
9.I [7-07] R/W
0: Disabled
1: Enabled
9.I [8-00] R/O
1
9.I [8-01] R/W 5~95 min, step: 5 min
30 min
9.I [8-02] R/W 0~10 hour, step: 0,5 hour
3 hour
9.I [8-03] R/W 20~95 min, step: 5 min
50 min
9.I [8-04] R/W 0~95 min, step: 5 min
95 min
9.I [8-05] R/W
0: No
1: Yes
9.I [8-06] R/W 0~10°C, step: 1°C
5°C
9.I [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
9.I [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
9.I [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
9.I [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
9.I [8-0B]
13
9.I [8-0C]
10
9.I [8-0D]
16
9.I [9-00] R/W [2-0C]=2:
37~60, step: 1°C
60°C
[2-0C]2:
37~55, step: 1°C
55°C
9.I [9-01] R/W 15~37°C, step: 1°C
25°C
9.I [9-02] R/W 18~22°C, step: 1°C
22°C
9.I [9-03] R/W 5~18°C, step: 1°C
7°C
9.I [9-04] R/W 1~4°C, step: 1°C
4°C
9.I [9-05] R/W 15~37°C, step: 1°C
25°C
9.I [9-06] R/W [2-0D]=2:
37~60, step: 1°C
60°C
[2-0D]2:
37~55, step: 1°C
55°C
9.I [9-07] R/W 5~18°C, step: 1°C
7°C
9.I [9-08] R/W 18~22°C, step: 1°C
22°C
9.I [9-09] R/W 1~18°C, step: 1°C
18°C
9.I [9-0A] R/W [3-07][3-06]°C, step: 0,5°C
23°C
9.I [9-0B] R/W [3-09][3-08]°C, step: 0,5°C
23°C
9.I [9-0C] R/W 1~6°C, step: 0,5°C
1 °C
9.I [9-0D] R/W 0~8, step:1
0 : No limitation
1~4 : 80~50%
5~8 : 80~50% during sampling
6
9.I [9-0E]
6
9.I [C-00] R/O
1
9.I [C-01]
0
--
Domestic heating water priority.
--
What is the room buffering temperature in heating?
What is the room buffering temperature in Cooling?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
What is the allowed undershoot in cooling?
Room temperature hysteresis.
Pump speed limitation
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
--
--
--
Anti-recycling time.
Booster heater delay timer.
Additional running time for the maximum running time.
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
--
Boiler efficiency
HP Forced OFF
BBR16 activation
Minimum running time for domestic hot water operation.
Maximum running time for domestic hot water operation.
What is the desired DHW production type?
What is the maximum DHW temperature setpoint?
Domestic hot water booster heater overshoot temperature.
Domestic hot water booster heater hysteresis.
How many leaving water temperature zones are there?
--
What is the capacity of the bottom plate heater?
What is the hysteresis to be used in reheat mode?
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
--
--
4P627274-1 - 2020.09 (#) Setting is not applicable for this unit.
(*1) EWAA*