FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
183
3P572321-4B
6
3. Flaring the pipe end
WARNING
• Donotapplymineraloiltotheare.
• Prevent mineral oil from getting into the system as this would reduce the service life of the units.
• Never use piping which has been used for previous installations. Only use parts which are delivered with this unit.
• Never install a dryer to this R410A unit in order to guarantee its service life.
• The drying material may dissolve and damage the system.
• Incompletearingmayresultinrefrigerantgasleakage.
CAUTION
• Do not reuse joints which have been used once already.
1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing
downward,sothatthelingsdonotenterthe
pipe.
3) Putthearenutonthepipe.
4) Flare the pipe.
5) Checkthatthearinghasbeendonecorrectly.
Check
Theare’sinner
surfacemustbe
aw-free.
Whenaring,do
notover-tighten
andcrack.
Thepipeendmust
beevenlyaredin
aperfectcircle.
Makesurethatthe
arenutistted.
Setexactlyatthepositionshownbelow.
Flaring
A
Die
A
0-0.020inch
(0-0.5mm)
Clutch-type
FlaretoolforR410A
0.039-0.059inch
(1.0-1.5mm)
Clutch-type(Rigid-type)
0.059-0.079inch
(1.5-2.0mm)
Wing-nuttype(Imperial-type)
Conventionalaretool
Cutexactlyat
rightangles.
Removeburrs.
4. Refrigerant piping
CAUTION
• Usethearenutxedtothemainunit.(Thisistopreventthearenutfromcrackingasaresultofdeteriorationovertime.)
• Topreventgasleakage,applyrefrigerationoilonlytotheinnersurfaceoftheare.(UserefrigerationoilforR410A.)
• Useatorquewrenchwhentighteningthearenutstopreventdamagetothearenutsandgasleakage.
• Alignthecentersofbotharesandtightenthearenuts3or4turnsbyhand,thentightenthemfullywithaspanneranda
torque wrench.
Do not apply refrigeration
oil to the outer surface.
Flare nut
Apply refrigeration
oil only to the inner
surfaceoftheare.
Do not apply refrigeration oil to
thearenuttoavoidtightening
withexcessivetorque.
Apply oil
Torquewrench
Piping union
Flare nut
Spanner
Tighten
01_EN_3P572321-4B.indd 6 2019/10/17 14:46:59