352
FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
14. Options
14.1 Option List
14.1.1 Indoor Unit
FTX Series
Option Name 09/12 Class 15 Class 18/24 Class
1 Wireless LAN connection adaptor
BRP072A43
+ KRP067A41
BRP072A43
+ KRP980B2
BRP072A43
2
Wired remote controller 1
BRC944B2
+ KRP067A41
BRC944B2
+ KRP980B2
BRC944B2
3
Wired remote controller cord
(shielded wire)
Length 9.8 ft (3m) BRCW901A03
Length 26.3 ft (8m) BRCW901A08
4
Wiring adaptor for timer clock / remote controller 2
(normal open pulse contact / normal open contact)
KRP413BB1S
+ KRP067A41
KRP413BB1S
+ KRP980B2
KRP413BB1S
5
Central remote controller 3
DCS302C71
6
Unied ON/OFF controller 3
DCS301C71
7
Schedule timer controller 3
DST301BA61
8 Interface adaptor for Dlll-NET (residential air conditioner)
KRP928BB2S
+ KRP067A41
KRP928BB2S
+ KRP980B2
KRP928BB2S
9 Interface adaptor for residential air conditioner KRP067A41 KRP980B2 —
10 Titanium apatite deodorizing lter (without frame)
KAF970A46 4
11 Remote controller loss prevention with chain KKF936A4 KKF910A4
Notes: 1 A wired remote controller cord BRCW901A03 or BRCW901A08 is necessary.
2 Timer clock and other device ; obtained locally.
3 An interface adaptor (KRP928BB2S) is also required for each indoor unit.
4 Standard accessory.
FVXS Series
Option Name Model Name
1 Wireless LAN connection adaptor BRP072A43
2
Wiring adaptor for timer clock / remote controller 1
(normal open pulse contact / normal open contact)
KRP413BB1S
3
Central remote controller 2
DCS302C71
4
Unied ON/OFF controller 2
DCS301C71
5
Schedule timer controller 2
DST301BA61
6 Interface adaptor for Dlll-NET (residential air conditioner) KRP928BB2S
7 Titanium apatite deodorizing lter (without frame) KAF968A42 or KAF968B42
8 Remote controller loss prevention with chain KKF910A4
Notes: 1 Timer clock and other device ; obtained locally.
2 An interface adaptor (KRP928BB2S) is also required for each indoor unit.
FDMQ Series
Option Name Model Name
1 Remote controller (required)
Wired type1 1
BRC1E73
Wireless type BRC082A43
2 Central remote controller DCS302C71
3 Unied ON/OFF controller DCS301C71
4 Schedule timer controller DST301BA61
5 Remote sensor KRCS01-4B
6 Remote controller loss prevention with chain KKF910A4
7
Wiring adaptor 2
KRP1C74
8 Installation box for adaptor PCB KRP4A98
Notes: 1 Wiring for wired remote controller should be obtained locally.
2 Installation box for adaptor PCB (KRP4A98) is necessary.

Table of Contents