EasyManuals Logo

Daikin FTYN35GXV1B User Manual

Daikin FTYN35GXV1B
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
SiBE01-829 Troubleshooting
Service Diagnosis 43
4. Troubleshooting
4.1 Error Codes and Description
: Displayed only when system-down occurs.
Code Description
Reference
Page
System
00
Normal
U0
Insufficient gas 53
UA
Hardware error (tact switch pin short) 52
Indoor
Unit
A1
Indoor unit PCB abnormality 44
A5
Freeze-up protection control, high pressure control or indoor heat
exchanger thermistor abnormality
45
A6
Fan motor or related abnormality (AC motor) 47
C4
Heat exchanger thermistor abnormality 48
C9
Room temperature thermistor abnormality 48
Outdoor
Unit
F6
High pressure control in cooling or outdoor heat exchanger
thermistor abnormality
50
J6
Heat exchanger thermistor or related abnormality 52

Table of Contents

Other manuals for Daikin FTYN35GXV1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTYN35GXV1B and is the answer not in the manual?

Daikin FTYN35GXV1B Specifications

General IconGeneral
BrandDaikin
ModelFTYN35GXV1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals