Indoor Unit SiBE01-829
82 Removal Procedure
1.9 Exchange of Drain Hose
Procedure Warning Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1
Remove the fixing
screw on the right side
and remove the drain
hose.
To prevent water leakage,
make sure to mount the
fixing screw as it was.
2
Remove the drain cap
located at the left side.
Use a 4mm Allen wrench.
(R8631)
Drain hose
Fixing screw
(R8632)
Drain cap
(R8633)