3-24
I/O ON
I/O
Power OFF
Unit OFF
All lights on
(for 3 sec.)
Preparation
(for 18 sec.)
Circuit Breaker ON
Circuit Breaker OFF
after setting change
( OFF when no setting changed)
for 3 sec. for 3 sec. for 3 sec. for 3 sec.
CASE 2CASE 1
CASE 3 (Refer to 3.8.2)
※ 10
Optional
Function
Setting
※ 11
Basic
Function
Setting
※ 12
Optional
Condition
Setting
※ 13
Container
I.D & Time
Setting
PTI
for 3 sec.for 3 sec.
USDA: OFF (or 3 or 4)
S
dHU: OFF (or ON)
DECOS3: C (or B or A)
S
Log. Interval: 30 (or 15 or 60 or 120)
S
REC SEN: ON (or OFF)
S
OC-SET: Sing (or Dual)
S
HP: 10 (or 5)
S
DISP: OFF (or ON)
S
COMP: 100 (or 33)
S
REHEAT: OFF (or ON)
Container I.D
S
Controller
Time
CHARTLS
: OFF (or ON)
S
USDA 1/2: 2 (or 1)
S
H001~H006
S
d-1**~d-2**
S
C/F : C (or F)
3.3.3 Setting flow chart
This configuration setting flow shall be utilized, when
CASE 1) USDA transportation setting is required (※10 Optional Function Setting)
CASE 2) Container ID shall to be subjected to change from another container for emergency use.
(※13 Container ID & Time Setting)
CASE 3) Controller is replaced to new one. (All setting in ※10-13 shall be set.)
NOTE 1 : All initial settings are pre-setted, when the unit is delivered.
2 : In case to complete the setting change, CIRCUIT BREAKER shall be turned off