EasyManua.ls Logo

Daikin Vision User Manual

Daikin Vision
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation and Maintenance Manual IM 915-13
Group: Applied Air Systems
Part Number: IM 915-13
Date: June 2023
Vision
®
Air Handler – Extended Sizes
Sizes 107—169
Question and Answer IconNeed help?

Do you have a question about the Daikin Vision and is the answer not in the manual?

Daikin Vision Specifications

General IconGeneral
BrandDaikin
ModelVision
CategoryAir Handlers
LanguageEnglish

Summary

General Information

Receiving and Handling

Steps for inspecting and handling incoming units to prevent damage.

Nomenclature

Explanation of Daikin Air Handler unit naming conventions and components.

Handling

Guidelines for safely handling Vision air handler units during installation.

Installation Guidelines

Service Clearances

Requirements for adequate space around the unit for service and maintenance.

Rigging

Assembling Sections

Horizontal Airflow Section Mounting

Detailed steps for mounting sections in horizontal airflow configuration.

Panels, Frame Channels, and Doors

Panel Removal

Procedure for safely removing side or top panels from the unit.

Frame Channel Removal

Instructions for removing frame channels to gain access to unit components.

Injected-Foam Insulated Panels

Panel Cutting Procedure

Steps for determining and cutting holes in insulated panels for components.

External Face and Bypass Duct Assembly

HEPA Holding Frame, Filter, and Prefilter Installation

AAF HEPA Filters without Prefilters

Instructions for installing HEPA filters without prefilters into holding frames.

AAF HEPA Filters with Prefilters

Mounting Actuators

Piping and Coils

Guidelines for designing and installing piping for coils and related components.

Steam Coils

Traps

Recommendations for sizing and installing traps for steam coil condensate removal.

Pipe Chases

Water Heating Coils

Drain Pan Traps

Instructions for installing drain pan traps to ensure proper condensate drainage.

Internal Fan Isolation Assembly Adjustment

Spring Mount Assembly (Class 1 & 2)

Spring Mount Assembly (Class 3)

Procedure for adjusting Class 3 spring mount assemblies for proper fan isolation.

Electrical Installation

Wiring

Guidance on connecting power and ground for fan motors and unit components.

Control Wiring

Instructions for connecting control signals, VFDs, and wiring for EC fans.

Operation Guidelines

Startup Checks

Essential pre-operation checks to ensure safe and correct unit startup.

Fan Startup

VFD Setup

Procedures for configuring Variable Frequency Drives for optimal fan operation.

Fan Wheel Alignment

Specifications and procedures for aligning fan wheels to the inlet funnel for optimal performance.

Daikin Applied Fan Array

Optional Piezometer Ring Airflow Measurement Device

Non-Standard Density Method

Equation for measuring airflow under non-standard air density conditions.

Standard Density Method

Simplified equation for measuring airflow under standard air density conditions.

Optional Transducer for Piezometer Rings

Daikin Applied EC Fan Array

Remote Mounted Panel

Instructions for mounting the control panel remotely and associated wiring.

Piezometer Point Airflow Measurement Device

Non-Standard Density Method

Equation for measuring airflow under non-standard air density using piezometer.

Standard Density Method

Equation for measuring airflow under standard air density using piezometer.

Fan Operating Limits

Fan Vibration Levels

Vibration Causes

Common reasons for fan vibration and potential issues.

Sorbent Ventilation Technology

Service and Maintenance

Periodic Service and Maintenance

Schedule for checking moving parts, connections, and general inspection.

Bearing Lubrication

Procedures and recommended greases for bearing lubrication to prevent overheating.

Fan Drive Adjustments

Fan Shaft Bearings

Maintenance and lubrication specifics for fan shaft bearings.

Fan Drive Belt Adjustment

Front Load Filter Option

Instructions for removing and replacing filters from the front-loaded option.

Filter Gauges

Maintaining the Coil

Winterizing Water Coils

Procedures for protecting water coils from freezing during cold weather.

Removing and Replacing Components

General guidance on safely removing and replacing unit components.

Removing the Fan Assembly

Removing and Replacing the Coil

Instructions for removing and replacing coils from the unit section.

Removing Stacked Coils

Installing Stacked Coils

Steps for installing stacked coils into the unit section, preventing air bypass.

Warranty

Warranty Return Material Procedure

Steps for returning defective material for warranty claims and processing.

Replacement Parts

Information required when ordering service or replacement parts for the unit.

Equipment Warranty Registration Form

Quality Assurance Survey Report

Daikin Applied Training and Development

Aftermarket Services

How to find local parts and service offices for support.

Related product manuals