EasyManuals Logo

DALCNET Adeo Control SGDD-C4-4 User Manual

DALCNET Adeo Control SGDD-C4-4
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Adeo Group s.r.l.
Via della Zarga n. 50 - 38015 LAVIS (TN)
Tel: +39 0461 248211 - Fax: +39 0461 245038
Mail: info@adeogroup.it www.adeogroup.it
Adeo Control SGDD-C4-4
Manual
Rev. 1.6
Ad e o C o n t r o l i s a b r a n d o f A d e o G ro up s . r .l .
31 / 36
Connected On Channel Automatically shows the channel assigned in Connections
Min Temperature In Kelvin Set the minimum value in Kelvin
Max Temperature In Kelvin Set the maximum value in Kelvin
DALI Curve Off to maintain a linear dimming (DMX type)
On to use the logarithmic dimming of DALI
Intensity Auto Preset Off to exclude the storage of the last light status before switch-off
On to store the last light status before switch-off
White Temperature Autoset Off to exclude the storage of the last temperature status before switch-off
On to store the last temperature status before switch-off
Logging
Log Level Off to disable logging in Lua
5 - Debug, 4 - Trace, 3 - Info, 2 - Warning, 1 - Error, 0 Alert set the Log Level.
The remote assistance requires 5 - Debug
Log Mode Print, Log and Print and Log
Disable Log Interval it is possible to set an interval within which to disable logging, so as to save processing
Driver Info
Driver Version Show Driver Version

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DALCNET Adeo Control SGDD-C4-4 and is the answer not in the manual?

DALCNET Adeo Control SGDD-C4-4 Specifications

General IconGeneral
BrandDALCNET
ModelAdeo Control SGDD-C4-4
CategoryGateway
LanguageEnglish