Operator's Manual for the DM100-2014 VDR
Copyright Danelec Marine A/S
a defective VDR data disk (i.e. the SDD inside the DPU). If the
error persists, the DPU must be repaired.
746
LONG-TERM, too many
read errors
Too many read-errors (reading back data from the VDR data disk)
have been detected by the over a period of time. The VDR was
unable to read back data despite several attempts. The most likely
cause is an internal problem in the DPU. If the error persists, the
DPU must be repaired.
747
LONG-TERM, too many
read errors
Too many read-errors (reading back data from the VDR data disk)
have been detected by the long-term disk over a period of time. The
VDR was unable to read back data despite several attempts. The
most likely cause is a defective VDR data disk (i.e. the SDD inside
the DPU). If the error persists, the DPU must be repaired.
748
LONG-TERM
Verification failed
The VDR found too many data errors within a given interval when
verifying the data written to the VDR data disk.
749
LONG-TERM
Record too big
The amount of data collected for a 15-second period has exceeded
the maximum allowed size for the VDR data disk. This is typically
caused by receipt of too much image data. Use the “Analysis of
recorded data” utility on the BCP or in the configurator tool to
determine the cause. If the problem relates to image data, carry out
an OPT and check the recorded images.
750
LONG-TERM
Record-data too big
The amount of data received by the VDR exceeds the capacity of
the VDR data disk. This is typically caused by receipt of too much
image data. Use the “Analysis of recorded data” utility on the BCP
or in the configurator tool to determine the cause. If the problem
relates to image data, carry out an OPT and check the recorded
images.
901-
933
SYSTEM FAILURE
ERROR 901-933
The software is not working properly. Restart the VDR and report
this error if it is repeated.
970
SELF-TEST
RAM size xxx MB,
Should be >= yyy MB
The amount of RAM is insufficient to start the VDR. Restart the
system, if the error persists then call for assistance.
971
SELF-TEST
xx network interfaces
found, 4 required
Required networking interfaces are not available to start the VDR.
Restart the system, if the error persists then call for assistance.
972
SELF-TEST
Failed to initialize
VGA
Required Video (VGA) circuitry could not be initialized. Restart
the system, if the error persists then call for assistance
983
No communication
to DPU
The BCP has never been able to communicate with the DPU. The
most probable cause is a defective cable or that the VDR did not
boot up correctly.
984
No communication
to DPU
The initial communication was functional but the communication
has failed at some point. The most probable cause is that the VDR
has encountered a system error and completely stopped. Restart the
VDR. If the error persists, the DPU is probably defective.
DBS11011-12 Page 26/27