4. Transmission Test
Initiate transmission test on room thermostat (fig. 1)
Press the push button .
LED goes ON.
Link test is satisfactory
LED goes OFF.
Link test is unsatisfactory
LED flashes 5 times.
No Link connection to room thermostat
Try to relocate room thermostat in the room.
Or install CF-RU Repeater Unit and locate between
Master Controller and room thermostat.
Note: When connected to a room thermostat, the Master
Controller output LED(s) flash(es) during Link test.
Instruction CF-RF Room Thermostat with Infrared Floor Sensor