2.1.9 Changing Data
The procedure for changing data is the same whether you select a parameter in the Quick menu or the Main menu mode. Press [OK] to change the
selected parameter.
The procedure for changing data depends on whether the selected parameter represents a numerical data value or a text value.
2.1.10 Changing a Text Value
If the selected parameter is a text value, change the text value by means
of the [
] [
] navigation keys.
The up key increases the value, and the down key decreases the value.
Place the cursor on the value you want to save and press [OK].
130BP068.10
2.1.11 Changing a Group of Numeric Data Values
If the chosen parameter represents a numeric data value, change the
chosen data value by means of the [
] [
] navigation keys as well as
the [
] [
] navigation keys. Use the [
] [
] navigation keys to move
the cursor horizontally.
130BP069.10
Use the [
] [
] navigation keys to change the data value. The up key
enlarges the data value, and the down key reduces the data value. Place
the cursor on the value you want to save and press [OK].
130BP070.10
2.1.12 Changing a Data Value, Step-by-Step
Certain parameters can be changed step by step or infinitely varying. This applies to par.1-20
Motor Power [kW]
, par.1-22
Motor Voltage
and par.
1-23
Motor Frequency
.
The parameters are changed both as a group of numeric data values and as numeric data values infinitely varying.
2.1.13 Read-out and Programming of Indexed Parameters
Parameters are indexed when placed in a rolling stack.
par.15-30
Alarm Log: Error Code
to par.15-33
Alarm Log: Date and Time
contain a fault log which can be read out. Choose a parameter, press [OK], and
use the up/down navigation keys to scroll through the value log.
2 How to Programme ADAP-KOOL
®
Drive Programming Guide
28
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ADAP-KOOL Drive and is the answer not in the manual?

Danfoss ADAP-KOOL Drive Specifications

General IconGeneral
BrandDanfoss
ModelADAP-KOOL Drive
CategoryDC Drives
LanguageEnglish

Related product manuals