Parameter 12-24 Process Data Config Read Size
Table 624: Parameter 12-24 Process Data Config Read Size
12-24 Process Data Config Read Size
Parameter type: Range, 8 - 32
Change during operation: True
Use this parameter to configure the PCD read size in bits. Only values of multiples of 8 are valid.
Parameter 12-27 Master Address
Table 625: Parameter 12-27 Master Address
Parameter type: Range, 0 - 4294967295
Change during operation: False
Parameter 12-28 Store Data Values
Table 626: Parameter 12-28 Store Data Values
Change during operation: True
This parameter activates a function that stores all parameter values in the non-volatile memory (EEPROM) thus retaining parameter
values at power-down. The parameter returns to [0] Off.
Parameter 12-29 Store Always
Table 627: Parameter 12-29 Store Always
Change during operation: True
Activates a function that always stores received parameter data in the non-volatile memory (EEPROM).