DEVIreg™ 850 IV
Installation instruction4
When more than 1 area is controlled by the DEVIreg™ 850 system, it is also possible to
prioritize the areas. Prioritizing makes it possible to operate 2 areas, even if the needed
power for 2 areas is not present.
The DEVIreg™ 850 is fully automatic and operated digitally by means of the intelligent
sensors located in the heated terrain. Each sensor measures both temperature and mois-
ture, and the system turns the heating elements on and off based on these readings. By
combining moisture and temperature readings, the system is able to save around 75%
energy compared to systems which only measure temperature readings. The digital sen-
sors used for the DEVIreg™ 850 also provide the most exact readings when compared
with corresponding analogue systems. The result is optimum functionality and low en-
ergy consumption.
For more information about the ice and snow melting function of the DEVIreg™ 850,
please refer to: Appendix B: “How it works.
A typical installation consists of:
Controller unit (only one)
This is the device which, based on the measurements
from the sensors, decides when to heat the connected
area(s).
Power supply (one or more)
The power supply delivers power to the controller unit
and the connected sensors.
Ground sensor (one or more)
At least 1 ground sensor is needed for each ground area,
but to get the best performance of a system, 2 or more
sensors are recommended.
For more information please refer to the sensor manual.
Roof sensor (one or more)
At least 1 roof sensor is needed for each roof area, but
for complex roof constructions, 2 or more sensors are
recommended.
For more information please refer to the sensor manual.