0-20 Display Line 1.1 Small
Option: Function:
[1679] Analog Out X45/3
[mA]
[1680] Fieldbus CTW 1 Control word (CTW) received
from the bus master.
[1682] Fieldbus REF 1 Main reference value sent with
control word from the bus
master.
[1684] Comm. Option Status Extended serial communication
option status word.
[1685] FC Port CTW 1 Control word (CTW) received
from the bus master.
[1686] FC Port REF 1 Status word (STW) sent to the bus
master.
[1690] Alarm Word One or more alarms in a Hex
code.
[1691] Alarm word 2 One or more alarms in a Hex
code.
[1692] Warning Word One or more warnings in a Hex
code.
[1693] Warning word 2 One or more warnings in a Hex
code.
[1694] Ext. Status Word One or more status conditions in
a Hex code.
[1836] Analog Input X48/2
[mA]
[1837] Temp. Input X48/4
[1838] Temp. Input X48/7
[1839] Temp. Input X48/10
[1860] Digital Input 2
[1890] Process PID Error
[1891] Process PID Output
[1892] Process PID Clamped
Output
[1893] Process PID Gain
Scaled Output
[3019] Wobble Delta Freq.
Scaled
[3110] Bypass Status Word
[3111] Bypass Running Hours
[3401] PCD 1 Write to MCO
[3402] PCD 2 Write to MCO
[3403] PCD 3 Write to MCO
[3404] PCD 4 Write to MCO
[3405] PCD 5 Write to MCO
[3406] PCD 6 Write to MCO
[3407] PCD 7 Write to MCO
[3408] PCD 8 Write to MCO
0-20 Display Line 1.1 Small
Option: Function:
[3409] PCD 9 Write to MCO
[3410] PCD 10 Write to MCO
[3421] PCD 1 Read from MCO
[3422] PCD 2 Read from MCO
[3423] PCD 3 Read from MCO
[3424] PCD 4 Read from MCO
[3425] PCD 5 Read from MCO
[3426] PCD 6 Read from MCO
[3427] PCD 7 Read from MCO
[3428] PCD 8 Read from MCO
[3429] PCD 9 Read from MCO
[3430] PCD 10 Read from
MCO
[3440] Digital Inputs
[3441] Digital Outputs
[3450] Actual Position
[3451] Commanded Position
[3452] Actual Master Position
[3453] Slave Index Position
[3454] Master Index Position
[3455] Curve Position
[3456] Track Error
[3457] Synchronizing Error
[3458] Actual Velocity
[3459] Actual Master Velocity
[3460] Synchronizing Status
[3461] Axis Status
[3462] Program Status
[3464] MCO 302 Status
[3465] MCO 302 Control
[3470] MCO Alarm Word 1
[3471] MCO Alarm Word 2
[9913] Idle time
[9914] Paramdb requests in
queue
[9917] tCon1 time
[9918] tCon2 time
[9919] Time Optimize
Measure
[9920] HS Temp. (PC1)
[9921] HS Temp. (PC2)
[9922] HS Temp. (PC3)
[9923] HS Temp. (PC4)
[9924] HS Temp. (PC5)
[9925] HS Temp. (PC6)
[9926] HS Temp. (PC7)
[9927] HS Temp. (PC8)
Parameter Descriptions FC 300 Programming Guide
MG.33.MA.22 - VLT
®
is a registered Danfoss trademark 3-7
3
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss FC 300 Series and is the answer not in the manual?

Danfoss FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelFC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals