Displacement Limiter Adjustment
P104 469E
Limiting Screw
Locknut
(see table)
(see table)
1. Loosen the locknut.
2. Rotate the adjusting screw to achieve the desired maximum displacement.
3. Set the adjusting screw against the servo piston by feel before counting turns.
Refer to the table for change per turn. Clockwise rotation decreases displacement, counterclockwise
rotation increases it. Adjustment is possible from zero to maximum.
Approximate displacement change cm
3
[in
3
] per revolution
069 078 089 100 115 130 147 165 210 250 280
6.6
[0.40]
7.4
[0.45]
9.3
[0.57]
10.7
[0.65]
10.8
[0.66]
12.2
[0.74]
13 [0.79] 14.5
[0.88]
17.4
[1.06]
20.6
[1.26]
23.1
[1.41]
4. After establishing the desired maximum displacement setting, hold the adjusting screw while
torquing the locknut to the value in the table below.
Displacement Limiter Adjustment Data
Frame 069/078 089/100 115/130, 147/165,
210/250/280
Locknut wrench size, torque 13 mm, 24 N•m [18
lb•ft]
17 mm, 48 N•m [35
lb•ft]
22 mm, 80 N•m [59 lb•ft]
Adjusting screw wrench size 4 mm 5 mm 6 mm
5. Test operation of the vehicle/machine to verify proper maximum speed of vehicle/work function.
Control Neutral Adjustment
All functions of the Electric Displacement Control (EDC), are preset at the factory. If necessary, adjust the
pump to neutral with the pump running on a test stand or on the vehicle/machine with the prime mover
operating. If adjustment fails to give satisfactory results, you may need to replace the control or coils. See
Minor repair for details.
Service Manual
H1P 069—H1P 280 Axial Piston Single Pumps
Adjustments
38 |
©
Danfoss | January 2021 AX152886482551en-000601