FREQUENCY
001 LANGUAGE
ENGLISH
50.0 Hz
The 3rd line of the display shows the parameter num-
ber and name, while the status/value of the selected
parameter is shown in line 4.
Changing data
Regardless of whether a parameter has been selected
under the Quick menu or the Menu mode, the proce-
dure for changing data will be the same. Pressing the
[CHANGE DATA] key gives access to changing the
selected parameter, following which the underlining in
line 4 will flash on the display. The procedure for
changing data depends on whether the selected pa-
rameter represents a numerical data value or a text
value.
Changing a data value
If the selected parameter is a text value, the text value
is changed by means of the [+ / -] keys.
50.0 Hz
FREQUENCY
001 LANGUAGE
ENGLISH
The bottom display line will show the value that will be
entered (saved) when acknowledgment is given [OK].
Change of numeric data value
If the selected parameter is represented by a numeri-
cal data value, a digit is first chosen using the [< >]
keys.
50.0 Hz
SETUP
1
FREQUENCY
130 START FREQUENCY
09.0 HZ
The selected digit can then be changed infinitely vari-
ably using the [+ / -] keys:
50.0 Hz
SETUP
1
FREQUENCY
130 START FREQUENCY
10.0 HZ
The chosen digit is indicated by the digit flashing. The
bottom display line shows the data value that will be
entered (saved) when signing off with [OK].
Manual initialisation
NB!
Manual initialisation is
not possible on the
LCP 2 175N0131 control unit. It is, how-
ever, possible to perform an initialisation
via par. 620 Operation mode:
The following parameters are not set to zero when in-
itialising via par. 620 Operation mode.
- par. 500 Address
- par. 501 Baud rate
-
par. 600 Operating hours
- par. 601 Hours run
- par. 602 kWh counter
- par. 603 Number of power-ups
- par. 604 Number of overtemperatures
- par. 605 Number of overvoltages
-
par. 615-617 Fault log