Accessories for the VLT 2800
Type Description Ordering no.
Motor coil The motor coil module can be used for VLT 2803-2875 195N3110
RFI 1B filter The RFI 1B filter module can be used for VLT 2803-2875 195N3103
RFI 1B/LC filter 4 A The RFI 1B/LC filter 4 A can be used for VLT 2803-2805
200-240 V and VLT 2805-2815 380-400 V
195N3100
RFI 1B/LC filter 9.1 A RFI 1B/LC filter 9.1 A can be used for VLT 2807-2815 200-240
V and VLT 2822-2840 380-400 V
195N3101
EMC filter EMC filter for long motor cables can be used for VLT 2805-2815
380-480 V
192H4719
EMC filter EMC filter for long motor cables can be used for VLT 2822-2840
380-480 V
192H4720
EMC filter EMC filter for long motor cables can be used for VLT 2855-2875
380-480 V
192H4893
NEMA 1 terminal cover VLT 2803-2815 200-240 V, VLT 2805-2815 380-480 V 195N1900
NEMA 1 terminal cover VLT 2822 200-240 V, VLT 2822-2840 380-480 V 195N1901
NEMA 1 terminal cover VLT 2840, VLT 2840 PD2 200-240 V, VLT 2855-2875 380-480
V
195N1902
IP 21 top cover VLT 2803-2815 200-240 V, VLT 2805-2815 380-480 V 195N2179
IP 21 top cover VLT 2822 200-240 V, VLT 2822-2840 380-480 V 195N2180
IP 21 top cover VLT 2840 200-240 V, VLT 2822 PD2, VLT 2855-2875 380-480
V
195N2181
IP 21 top cover VLT 2880-2882 380-480 V, VLT 2840 PD2 195N2182
LCP 2 control unit LCP 2 for programming the frequency converter 175N0131
Cable for LCP 2 control unit Cable from LCP 2 to frequency converter 175Z0929
DeviceNet cable Cable for DeviceNet connection 195N3113
LCP 2 remote-mounting kit Kit for remote-mounting of LCP 2 (incl. 3 m cable,
excl. LCP 2)
175Z0850
LOP (Local Operation Pad) LOP can be used for setting the reference
and start/stop via the control terminals.
175N0128
VLT Software Dialog
CD-ROM version
1
175Z0967
MCT 10 Set-up Software 130B1000
External heat sink, small
2
W x H x D = 222 x 450 x 65mm
3
195N3111
External heat sink, large
2
W x H x D = 288 x 450 x 71mm
3
195N3112
1)
Incl. the modules Basis, Logging, Template, Guided
Tour in 6 languages (Danish, English, German, Italian,
Spanish and French).
2)
For further information see
VLT 2800 Cold Plate Instruction MI.28.DX.02.
22 MG.27.E2.02 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT 2800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 2800 and is the answer not in the manual?

Danfoss VLT 2800 Specifications

General IconGeneral
Frequency50/60 Hz
EnclosureIP20
Input Voltage200-240V AC
Output Power Range0.37-2.2kW
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Communication InterfaceRS485
Operating Temperature-10°C to +40°C
Storage Temperature-25°C to +65 °C
Relative Humidity5 - 95% RH, non-condensing
Output Voltage0 - 100% of supply voltage