EasyManuals Logo

Danfoss VLT 5000 User Manual

Danfoss VLT 5000
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Synchronizing controller
MG.10.N4.02 - VLT is a registered Danfoss trademark 25
727
Test run; Program 1:
Test run distance: Specify here the distance for the test run in quad counts.
Synchronous operation; Program 2:
Hold speed: If Hold function “0“ was selected, enter here the speed as a percentage of
the maximum speed (Parameter 716).
728
Test run, program 1:
Synchronizing type (Sync type): This parameter is used to specify the type of synchroni-
zation used when optimizing the PID controller for synchronization by means of the virtual
master.
Setting range:
0 = Speed synchronizing
1 = Position synchronizing
Select “0” if you are going to use speed synchronizing in synchronous mode or select “1” if
you are going to use position or marker synchronizing in synchronous mode.
Synchronous operation; Program 2:
Delta hold speed: Specify the percentage by which the hold speed is to change when
Input 32 or 33 is activated during Hold mode.

Table of Contents

Other manuals for Danfoss VLT 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 and is the answer not in the manual?

Danfoss VLT 5000 Specifications

General IconGeneral
Frequency50/60 Hz
Output Voltage Range0-100% of input voltage
Protection FeaturesOvervoltage, Undervoltage, Overtemperature, Short circuit
Communication InterfacesRS-485
Ambient Temperature Range-10°C to +40°C
Enclosure RatingIP20, IP21, IP55
Input Voltage200-240V AC, 380-480V AC, 525-600V AC

Related product manuals