Synchronizing controller
36 MG.10.N4.02 - VLT is a registered Danfoss trademark
797
Test run; Program 1:
“Track error“: The track error is displayed in quad counts.
Synchronous operation; Program 2:
“Sync-error”: The synchronization error is displayed with the value calculated in Parameter
747.
798
“Slave speed”: The slave speed is displayed with the value calculated in Parameter 745.
799
“Master speed”: The master speed is displayed with the value calculated in Parameter
746.
Initializing the parameters
It is possible to restore parameter default values by means of the initialise function in parameter 620.
All parameter except parameter 500, 501, 600-605, 615-617 will be reset to factory default setting.
NOTE: The VLT must be in stop mode before initialising can be carried out.
Procedure for initialising:
1. Select initialise in parameter 620
2. Press the [OK] key
3. Set parameter 710 to “1”. Wait until it changes to “0”(app. 0.5 sec)
4. Switch off mains supply and wait until the display is dark
5. Switch on the mains supply

Table of Contents

Other manuals for Danfoss VLT 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 and is the answer not in the manual?

Danfoss VLT 5000 Specifications

General IconGeneral
Frequency50/60 Hz
Output Voltage Range0-100% of input voltage
Protection FeaturesOvervoltage, Undervoltage, Overtemperature, Short circuit
Communication InterfacesRS-485
Ambient Temperature Range-10°C to +40°C
Enclosure RatingIP20, IP21, IP55
Input Voltage200-240V AC, 380-480V AC, 525-600V AC

Related product manuals