34-54 Master Index
Position
34-55 Curve Position
34-56 Track Error
34-57 Synchronizing
Error
34-58 Actual Velocity
34-59 Actual Master
Velocity
34-60 Synchronizing
Status
34-61 Axis Status
34-62 Program Status Select the process read data for I/O Assembly Instances
101/151. Elements [2] and [3] of this array can be selected.
Elements [0] and [1] of the array are fixed.
10-13 Warning Parameter
Range: Function:
0
*
[0 - 65535] View a DeviceNet-specific Warning word. One bit is assigned to
every warning. Please refer to the DeviceNet Operating Instruc-
tions (MG.33.DX.YY) for further information.
Bit: Meaning:
0 Bus not active
1 Explicit connection timeout
2 I/O connection
3 Retry limit reached
4 Actual is not updated
5CAN bus off
6 I/O send error
7 Initialization error
8 No bus supply
9Bus off
10 Error passive
11 Error warning
12 Duplicate MAC ID Error
13 RX queue overrun
14 TX queue overrun
15 CAN overrun
10-14 Net Reference
Read only from LCP.
Select the reference source in Instance 21/71 and 20/70.
[0]
*
Off Enables reference via analog/digital inputs.
[1] On Enables reference via the fieldbus.
10-15 Net Control
Read only from LCP.
FC 100/ 200/ 300 DeviceNet 6. Parameters
MG.33.D3.02 - VLT
®
is a registered Danfoss trademark
63
6

Other manuals for Danfoss VLT FC 100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 100 Series and is the answer not in the manual?

Danfoss VLT FC 100 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 100 Series
CategoryDC Drives
LanguageEnglish

Related product manuals