Par. No. # Parameter description Default value 4-set-up Change during oper-
ation
Conver-
sion index
Type
3-0* Reference Limits
3-02 Minimum Reference ExpressionLimit All set-ups TRUE -3 Int32
3-03 Maximum Reference ExpressionLimit All set-ups TRUE -3 Int32
3-04
Reference Function null All set-ups TRUE - Uint8
3-1* References
3-10 Preset Reference 0.00 % All set-ups TRUE -2 Int16
3-11 Jog Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
3-13 Reference Site [0] Linked to Hand / Auto All set-ups TRUE - Uint8
3-14 Preset Relative Reference 0.00 % All set-ups TRUE -2 Int32
3-15 Reference 1 Source [1] Analog input 53 All set-ups TRUE - Uint8
3-16 Reference 2 Source [20] Digital pot.meter All set-ups TRUE - Uint8
3-17 Reference 3 Source [0] No function All set-ups TRUE - Uint8
3-19 Jog Speed [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
3-4* Ramp 1
3-41 Ramp 1 Ramp-up Time ExpressionLimit All set-ups TRUE -2 Uint32
3-42 Ramp 1 Ramp-down Time ExpressionLimit All set-ups TRUE -2 Uint32
3-5* Ramp 2
3-51 Ramp 2 Ramp-up Time ExpressionLimit All set-ups TRUE -2 Uint32
3-52 Ramp 2 Ramp-down Time ExpressionLimit All set-ups TRUE -2 Uint32
3-8* Other Ramps
3-80 Jog Ramp Time ExpressionLimit All set-ups TRUE -2 Uint32
3-81 Quick Stop Ramp Time ExpressionLimit 2 set-ups TRUE -2 Uint32
3-9* Digital Pot. meter
3-90 Step Size 0.10 % All set-ups TRUE -2 Uint16
3-91 Ramp Time 1.00 s All set-ups TRUE -2 Uint32
3-92 Power Restore [0] Off All set-ups TRUE - Uint8
3-93 Maximum Limit 100 % All set-ups TRUE 0 Int16
3-94 Minimum Limit 0 % All set-ups TRUE 0 Int16
3-95 Ramp Delay ExpressionLimit All set-ups TRUE -3 TimD
6.2.5 3-** Reference / Ramps
6 How to program the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
6-60
MG.11.A9.22 - VLT
®
is a registered Danfoss trademark
6

Other manuals for Danfoss VLT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT and is the answer not in the manual?

Danfoss VLT Specifications

General IconGeneral
Frequency50/60 Hz
EnclosureIP20, IP21, IP55, IP66
SeriesVLT
Control TechniqueFlux Vector Control
Output Voltage0-Vinput
Control MethodFieldbus
Communication InterfacePROFIBUS, CANopen
Protection FeaturesOverload, Overvoltage, Undervoltage, Short Circuit, Ground Fault
Cooling MethodLiquid Cooled
Storage Temperature-25°C to +70°C
Relative Humidity5-95% non-condensing
AltitudeUp to 1000m (3280ft) without derating, up to 4000m (13120ft) with derating
Operating Temperature-10°C to +50°C (14°F to 122°F)