6.1.2 Quick Set-up parameters
Parameters for Quick Set-up
0-01 Language
Option: Function:
Defines the language to be used in the display.
The adjustable frequency drive can be delivered with 2 different language packages. English and
German are included in both packages. The English cannot be erased or manipulated.
[0] * English Part of Language packages 1 - 2
[1] Deutsch Part of Language packages 1 - 2
[2] Francais Part of Language package 1
[3] Dansk Part of Language package 1
[4] Spanish Part of Language package 1
[5] Italiano Part of Language package 1
[6] Svenska Part of Language package 1
[7] Nederlands Part of Language package 1
[10] Chinese Language package 2
[20] Suomi Part of Language package 1
[22] English US Part of Language package 1
[27] Greek Part of Language package 1
[28] Bras.port Part of Language package 1
[36] Slovenian Part of Language package 1
[39] Korean Part of Language package 2
[40] Japanese Part of Language package 2
[41] Turkish Part of Language package 1
[42] Trad.Chinese Part of Language package 2
[43] Bulgarian Part of Language package 1
[44] Srpski Part of Language package 1
[45] Romanian Part of Language package 1
[46] Magyar Part of Language package 1
[47] Czech Part of Language package 1
[48] Polski Part of Language package 1
[49] Russian Part of Language package 1
[50] Thai Part of Language package 2
[51] Bahasa Indonesia Part of Language package 2
6 How to program the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
6-4
MG.11.A9.22 - VLT
®
is a registered Danfoss trademark
6

Other manuals for Danfoss VLT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT and is the answer not in the manual?

Danfoss VLT Specifications

General IconGeneral
Frequency50/60 Hz
EnclosureIP20, IP21, IP55, IP66
SeriesVLT
Control TechniqueFlux Vector Control
Output Voltage0-Vinput
Control MethodFieldbus
Communication InterfacePROFIBUS, CANopen
Protection FeaturesOverload, Overvoltage, Undervoltage, Short Circuit, Ground Fault
Cooling MethodLiquid Cooled
Storage Temperature-25°C to +70°C
Relative Humidity5-95% non-condensing
AltitudeUp to 1000m (3280ft) without derating, up to 4000m (13120ft) with derating
Operating Temperature-10°C to +50°C (14°F to 122°F)